Across various industries, leaks pose a significant threat to both property and operation continuity. From potential data loss in server rooms to structural damage in historical buildings, early leak detection is crucial to prevent costly repairs and downtime. Our water detection system, also known as a water leak monitoring system, caters to a wide range of applications, ensuring comprehensive protection for your valuable assets.

What Is A Leak Detection System?

A leak detection system is an electronic equipment used to detect leakage from any possible threat of water damage. It utilizes a network of sensors to continuously monitor for leaks 24/7. This proactive approach enables the system to identify leaks at their earliest stages, preventing them from escalating into major issues. Upon detecting a leak, the system instantly sends automated alerts to designated users, allowing for swift intervention to minimize potential damage. Additionally, the system boasts the ability to pinpoint the exact location of the leak, saving valuable time and resources during troubleshooting and repair processes.

Benefits of a Leak Detection System

Preventative Measures

Early Leak Detection:
Identifies leaks at their source before they cause significant damage, minimizing the risk of costly repairs and downtime.

Protects Valuable Assets:
Safeguards critical equipment and stored data in server rooms and data centers, preventing financial losses and operational disruptions.

Peace of Mind

24/7 Monitoring:
Offers continuous vigilance, allowing you to focus on other priorities with the knowledge that your property is protected.

Prompt Alerts:
Provides immediate notifications upon detecting a leak, enabling swift action to mitigate potential damage.

Enhanced Efficiency

Precise Leak Location:
Pinpoints the exact source of the leak, saving time and resources during troubleshooting and repair processes.

Reduced Water Waste:
Detects and addresses leaks promptly, preventing unnecessary water loss and associated environmental and financial impacts.

Applications:

  • Raised floor computer facility
  • Datacentre (IDC) for Banks,
    Finance, Logistics & etc.
  • Communications and server
    equipment rooms
  • ISP / Co-location facilities
  • Fibre optic switch sites
  • Underground hot water piping
  • Museums & Historical buildings
  • Elevator pits
  • Control rooms
  • Raised floor office area
  • Semiconductor plants
  • Water treatment plants
  • Libraries & Aquariums

Leak Detection System Components

Water Sensing Cable (C-WSC-XX)

Highly accurate and reliable, the C-WSC-XX water sensing cable is designed for use with both locating and non-locating leak detection panels, making it versatile for data center water leak detection systems. This cable effectively detects any water presence, triggering an alarm through the connected panel. Users can then pinpoint the exact leak location using the panel’s features.

Features:

  • Strong & durable
  • Expansion with mating end connectors
  • Available in pre-measured and custom lengths with pre-installed end connectors
  • Plenum to CL2P per UL rated & UL910 listed
  • RoHS compliance to EU Directive 2011/6s/EU
  • Non-flame propagating & self-extinguishing
  • Continuity and signal wire: 2 x 28AWG black conductive ETFE insulation
  • Sensing wire: 2 x 24AWG ETFT insulation
  • Core: Fire resistence Fluoropolymer

Locating Panel (C-LP)

The C-LP acts as the central hub of the leak detection system, functioning as a Sensor Interface Module (SIM). It not only detects leaks through connected cables but also communicates with the Building Management System (BMS) for centralized monitoring, ideal for large-scale water leak monitoring systems. The panel displays the current system status and boasts a built-in distance locating feature to pinpoint leak occurrences with ±0.5-meter accuracy.

Features:

  • Max length of sensing cable connected up to 900m
  • Max connected length of jumper cable connected up to 500m
  • Leakage alarm data log
  • Accuracy up to plus minus 0.5m
  • Built in RS485 modbus
  • Sound alarm: 90dB max

Non Locating Panel (C-NP)

The LEAD Leak Detection System also offers a cost-effective solution for basic leak detection with the non-locating panel (C-NP). This panel provides fundamental leak monitoring, communicating with the BMS for centralized awareness, and is suitable for applications where precise leak location is not essential.

Features:

  • Max length of sensing cable connected up to 200m
  • Max connected length of jumper cable connected up to 100m
  • Accuracy up to plus minus 0.5m
  • Built in RS485 modbus
  • Sound alarm: 90dB max